1. To disconnect blocks of gray color. |
|
2. To measure by an ohmmeter resistance between contacts "1" and "2", it has to be about 1 kOhm. If resistance differs from specified, it is necessary to replace the sensor. |
3. After that to measure resistance between contacts "1" and "3", then between contacts "2" and "3". In both cases the ohmmeter has to show zero. If is though any resistance, to replace the frequency sensor. |
4. To check conducting between a block of the sensor of frequency and a block of the control unit of ignition. For this purpose to disconnect a connecting block from the block. |
|
5. To measure by an ohmmeter resistance between contacts "1" and "29", then between "2" and "11" and, at last, between "3" and "28" (see rice. Numbers of contacts of a connecting block of the control unit. |
6. Resistance has to be equal in all cases to zero. If the ohmmeter shows any resistance, means in conducting there is a break. |