1. To turn the water pump counterclockwise, previously having pulled a belt that it did not come off cogwheels. An assembly shovel or a screw-driver to turn the water pump counterclockwise, having pulled a belt. To tighten bolts of fastening of the water pump. |
2. To check a belt tension. The belt has to be overwound no more than on 90 ° by effort of big and index fingers. |
3. Finally to tighten bolts of fastening of the water pump the moment of 20 N · m (2,0 kgfs · м). |
|